Power Anaysers
Single and Three Phase Power Analysers Model 4106A Series
Features
- Suitable for frequency inverter drives
- Large and bright display for up to 10 values
- Scope function, 20 setups can be stored
- Harmonics 1-99, Bar charts
- DC-300kHz, 15mA-40A, 0.3V-1000V
- 0.1% accuracy
For more information about this product contact Tinsley
|
|

|
Introduction
Tinsley offer two state of the art high performance power analysers, single and three phase. Unlike other instruments at this price level the 4106A is designed to cope with the extreme signals generated on frequency inverter drives. You don't have to worry about the signal wave forms. The analysers will always provide precise and reliable measurements. The large and very bright monitor lets you read the display values from a distance of up to 4m.
Simple to use
The 4106A can be used for something as simple as measuring the power requirement of your coffee machine to a task as complex as determining the pertinent power parameters of a frequency inverter driven system.
All values are displayed in large characters, easily readable even in darkened environments. The user menu makes operation easy. The measured values can either be printed, sent to a PC via IEEE- or RS232 interface, or to a chart recorder via the analog outputs. You can have all available options installed or just the ones you require.
Extraordinary features, attractive display
Much effort has been put into the design of the 4106A Power Analysers to give you the highest performance at low cost. The analyser inputs are all galvanically isolated, are broad band DC-300kHz, have a wide input range (0.3V - 1000V, 15mA - 40A) and have an exceptional common mode rejection for use in frequency inverter driven systems. The accuracy is 0.1% (0.05% versions are available). The bright LCD monitor displays up to 10 measured values in highly legible 9mm high numbers.
The Three Phase Power Analyser puts up to 32 measured values on the screen. You have the choice to display wave forms, bar graphs or trend plots. A unique feature of these instruments allows a combination of meter mode and graphic mode.
Designed to last
With future development and as features are added to the 4106A you will be able to obtain upgrades, at modest cost, through your local Tinsley distributor. The Power Analysers are warranted for one year and are supplied with a traceable calibration certificate.
Model 4106A Specifications
See the table below for a run-down of this product's specifications.
Voltage |
8 ranges, 1-3-10-sequence; 0.3V, 1V, 3V, 10V, 30V, 100V, 300V, 1000V |
| |
Frequency range |
DC, 0.1Hz-300kHz |
| |
Crest Factor |
4:1 at 50% full scale (fs) |
| |
Input Impedance |
>1MΩ |
| |
Common Mode 50Hz/100kHz |
155dB/95dB |
| |
Standard accuracy 23°C ±3°C; rms, mean, rectified mean; for 0.3, 1V range, input >50% fs |
improved accuracy |
| |
1Hz-1kHz |
±(0.1% range + 0.1% range) |
±(0.05% rdg + 0.05% range ) |
| |
DC, 1kHz-10kHz |
±(0.2% range + 0.2% range) |
| |
10kHz-100kHz |
±(0.3% range + 0.04%/kHz range)* |
* 0.3V range typical |
| |
100kHz-300kHz |
±(0.3% range + 0.04%/kHz range), typical |
| |
|
Current |
10 ranges 1-3-10-sequence; 15mA,50mA,150mA,500mA,1.5A,5A; 1,3,10,30,100,300A |
| |
Frequency range |
DC, 0.1Hz-300kHz |
| |
Crest Factor |
4:1 at 50% full scale (fs) |
| |
Common Mode |
50Hz/100kHz |
160dB/120dB |
| |
Standard accuracy 23°C |
±3°C 5A-/Shunt input1 |
30A input1 |
improved accuracy 1Hz-400Hz±(0.05% rdg + 0.05% range) |
| |
1Hz-1kHz |
±(0.1% range + 0.1% range) |
±(0.1% range + 0.1% range) |
| |
DC, 1kHz-10kHz |
±(0.2% range + 0.2% range) |
±(0.9% range + 0.2% range) |
| |
10kHz-100kHz |
±(0.3% range + 0.04%/kHz range) |
±(0.3% range + 0.5%/kHz rdg) |
1for 2 lowest ranges, input>50% fs |
| |
100kHz-300kHz |
±(0.3% range + 0.04%/kHz range), typical |
|
| |
|
Power |
80 ranges corresponding to the product V x A |
|
Frequency range |
DC, 0.1Hz-300kHz |
|
Accuracy 23°C ±3°C |
|
1Hz-1kHz |
(Add accuracy percentage figures of current and voltage input and add 0.04%/kHz of Vrms x Arms / PF) |
PF = 0 to ±1 |
|
DC, 1kHz-10kHz |
PF = 0 to ±1 |
|
10kHz-100kHz |
PF = 1 |
| |
|
Frequency |
0.1Hz-300kHz, A or V triggered; Accuracy ±0.1% |
| |
|
|
Computed Values |
Accuracy; Reactive Power, Var = ±(VA2– W2)1/2; Apparent Power: VA = Arms Vrms; Power Factor: PF = W/VA; Crest Factor: CF = Ap/Arms, Vp/Vrms; Form Factor:FF = At/Arms, Vt/Vrms; Impedance: Z = Vrms/Arms; Total Harm Dist: THD = (Irms2 - IFund2)1/2/Irms |
Add accuracy percentage figs of values involved incomputation. |
| |
|
Integrator |
Energy, Charge; Accuracy Wh, VAh, Varh, Ah; Basic accuracy of integrated quantity. |
|
|
|
Harmonic Analysis |
Frequency range of fundamental |
2.5Hz-100kHz |
| |
Range of harmonic |
1-99 |
| |
Accuracy, Harmonic current and voltage |
| |
2Hz-1kHz |
±(0.2% rdg + 0.1% range) |
| |
1kHz-10kHz |
±(0.5% rdg + 0.5% range) |
| |
10kHz-100kHz |
±(0.7% range + 0.1%/kHz rdg),typical |
| |
|
Display |
Blue liquid crystal graphic display with FL backlight; 64x120mm; 128x240 pixels |
| |
|
|
Power |
AC, 50-400Hz; Fuse: Power |
85V-240V; 2AF/30VA |
|
|
|
Dielectric
Strength |
Inputs to case or power supply |
2.5kV/50Hz/1 minute |
| |
Line input to case |
1.5kV/50Hz/1 minute |
| |
Input to Input |
4kV/50Hz/1 minute |
| |
|
|
Dimensions |
H x W x D; Weight |
150 x 235 x 320mm; 4kg |
|
|
Options |
IEEE-488-2, RS232, Centronics printer output |
| |
4 Analog outputs, Output impedance 100Ω |
0 - ±5V |
| |
4 Analog inputs, low range, input impedance 200kΩ |
0 - ±1V |
| |
4 Analog inputs, high range, input impedance 200kΩ |
0 - ±10V |
| |
Rack mounting kit |
| |
Humidity: KYG according to DIN 40040, max. 85% RH non-condensing |
| |
|
Versions
4106A-1/0.1 |
Single Phase Power Analyser, 0.1% accuracy,
nonvolatile memory to save 20 instrument settings. |
4106A-1/0.05 |
Single Phase Power Analyser, 0.05% accuracy, nonvolatile
memory to save 20 instrument settings. |
4106A-1/nh |
Single Phase Power Analyser, without harmonics, without
graphics, 0.1% accuracy, nonvolatile memory to save 20
instrument settings. |
4106A-3/0.1 |
Three Phase Power Analyser, 0.1% accuracy, nonvolatile
memory to save 20 instrument settings. |
4106A-3/0.05 |
Three Phase Power Analyser, 0.05% accuracy, nonvolatile
memory to save 20 instrument settings. |
4106A-3/nh |
Three Phase Power Analyser, without harmonics without
graphics, 0.1% accuracy, nonvolatile memory to save 20
instrument settings. |
| |
|
Accessories
ACS1 |
Current clamp with connector to 4106A shunt input; 0-200A /
0-1000A, DC-1kHz, basic accuracy 2%. Other ranges and
accuracies on request
|
ACS2 |
Portable printer (106 x 180 x 88mm) with Centronics
interface and cable (400g)
|
ACS3 |
Soft carrying case for 4106A
|
ACS4 |
Set of test leads, max. 32A, 1.5m (2 red; 2 black)
|
ACS5 |
Shunt input connector
|
ACS6 |
Service Manual for 4106A
|
ACS7 |
Rack Mounting Kit
|
ACS8 |
Calibration Certificate traceable to National Standards
|
ACS9 |
USB - RS232 Adapter cable, USB 1.1 compatible, Windows
98/2000/ME/XP, > 1Mbps data transfer rate
|
Options
01 |
RS-232 Interface and Centronics printer output
|
02 |
RS-232 and IEEE-488 Interface, Centronics printer output
|
03 |
RS-232 and IEEE-488 Interface, Centronics printer output, 4 analog utputs, 8 analog inputs
|
03A |
RS-232 and IEEE-488 Interface, Centronics printer output, 4 analog outputs with provision to also output total power, 8 analog inputs
|
04 |
3-Phase current sensor module 0-100A (supply by 4106A)
|
05 |
Operating software under DOS to control 4106A, read data and store data via RS-232 or IEEE-488 (National / Keithley interface)
|
06 |
4106A driver for Nat. Instrument LabView
|
07 |
Standalone 4106A software based on LabView
|
07M |
Software for Motor Testing
|
07T |
Software for Transformer Testing
|
08 |
TTL-input for external synchronisation
|
09 |
Network to form artificial neutral (mainly for frequency inverter measurements)
|
10 |
0-300A, 0-3000A flexible current clamps with connector to clamp input of Power Analyser (1 per phase). Basic accuracy: 1% at 50/60Hz
|
For more information about this product contact Tinsley
|