Power Anaysers
Single and Three Phase Power Analysers Model 4107A Series
Features
- DC-300 kHz, 100 mA-50A, 1 V-1000 V
- Large and bright display for up to 10 values
- Line-to-line voltage, torque, slip, efficiency
- Harmonics 1-63, IEC1000-3-2
- High speed data logging for dynamic processes
- High speed dynamic torque measurement
- Advanced operating software under Windows
- Accuracy grades 0.05, 0.1, 0.3 % (low cost)
- Determines torque without using transducers
For more information about this product contact Tinsley
|
|

|
Introduction
The model 4107A High Speed Power Analyser is a very advanced measurement tool designed to offer the scientist, engineer, or technician more electrical and mechanical signal information than is normally found in one single instrument.
High performance - Easy to use
The Tinsley model 4107A Power Analysers are multipurpose instruments designed for laboratory and field use, for production testing and quality control. High accuracy, wide frequency range, and high common mode rejection are prerequisites for precision measurements on inverters, light ballasts, and ultrasonic transducers. The 4107A measurement capabilities and simplicity of use are unmatched.
Six menu soft keys M1 through M6 and five cursor soft keys control the instrument. The procedure to configure the display and interface, or to store instrument settings, such as the scaling factors, selecting the operating mode, selecting the input ranges, and many more features are self explanatory. You can save your personal instrument settings and have the unit start-up with your personal configuration at power-on.
Efficient data processing permits simultaneous measurements on all three phases of a three phase system and yields comprehensive signal information including rms and power values, harmonics, phase angles, and where applicable mechanical power output, torque, efficiency, and slip.
A programmable data logging function permits transfer of up to 500 rms and power values per second to a personal computer. The Tinsley operating software easily produces plots of power versus time or speed, or current versus time or frequency. The 4107A Power Analysers determines electrical motor torque applied to its load. No torque
transducers are needed. Induction motors and dc motors require a speed transducer, synchronous motors do not. A special operating mode for dynamic torque measurement in the air gap of a generator or motor provides plots of torque versus speed, frequency or time, and helps to detect undesirable peaks.
Model 4107A Specifications
See the table below for a run-down of this product's specifications.
Voltage |
7 ranges: 1V, 3V, 10V, 30V, 100V, 300V, 1000V |
|
Frequency range |
DC–300kHz |
Coupling: AC/AC+DC |
1Hz–300kHz / DC–300kHz |
|
Crest Factor |
3:1 at 50% full scale |
Common Mode 50Hz / 100kHz |
140dB/80dB |
|
Built-in star point network |
500kΩ Maximum Input: Hi to Lo / Lo to case |
1000V / 600V |
|
Accuracy 23°C ±3°C; rms, rdg= reading |
|
1Hz–1kHz |
±k(0.05% rdg + 0.07% range) |
Accuracy Grades: k=1, k=2, k=6 |
|
1kHz–10kHz |
±k(0.2% rdg + 0.2% range) |
|
10kHz–80kHz |
±k(0.04%/kHz rdg + 0.3% range) |
|
80kHz–300kHz |
±k(0.04%/kHz rdg + 0.3% range), typical |
| |
|
|
Current |
10 ranges: 100mA, 300mA, 1A, 3A,10A; 1, 3, 10, 30, 100A |
Clamp: 1A – 1000A |
| |
Frequency range: DC-300kHz |
Coupling: AC/AC+DC |
1Hz–300kHz / DC–300kHz |
| |
Crest Factor 3:1 at 50% full scale |
Common Mode 50Hz / 100kHz |
160dB/115dB |
| |
3A input: 3A cont./10A 5s; 50A input: 40A cont./50A 20s. |
RI=30mΩ/ 3mΩ |
| |
Accuracy 23°C ±3°C; rdg= reading, rng= range |
| |
|
50A/Clamp input |
3A input |
Accuracy Grades: k=1, k=2, k=6 |
| |
1Hz–500Hz |
±k(0.07% rdg + 0.07% rng) |
±k(0.07% rdg + 0.07% rng) |
| |
500Hz–2kHz |
±k(0.5% rdg + 0.5% rng) |
±k(0.8% rdg + 0.8% rng) |
| |
2kHz–10kHz |
±k(0.8% rdg + 0.8% rng) |
±k(2% rdg + 1% rng)* |
| |
10kHz–100kHz |
±k(0.1%/kHz rdg + 0.8% rng)* |
±k(0.1%/kHz rdg + 2% rng)* |
| |
Lowest range multiply percentage figures by 2. * typical |
|
|
|
Power |
70 Ranges corresponding to the product of the voltage ranges x current ranges. |
DC-300kHz |
| |
Accuracy 23°C ±3°C; 50A Clamp input, 3A input |
|
| |
1Hz–1kHz |
Add accuracy percentage figures of current and voltage input |
PF = 0 to ±1 |
| |
1kHz–100kHz |
Add accuracy percentage figures of current and voltage input,
add ±1% (1-PF)/kHz of range |
|
|
|
Computed Values |
Reactive Power, Var = ±(VA2 - W2)1/2;
Apparent Power: VA = Arms Vrms; |
| |
Power Factor: PF = W/VA; Crest Factor:
CF = Ap/Arms, Vp/Vrms; Maximum = Ap, Vp; |
Add accuracy percentage figures of values involvedin computation. |
| |
Minimum: -Ap, -Vp; PtP: Maximum–Minimum; Impedance: Z = Vrms/Arms |
| |
Total Harm Dist:
THD1 = (Irms2 - IFund2)1/2/Irms
THD2 = (I2rms2 + I3 rms2 + Irms2)1/2/Irms |
| |
|
|
Mechanical Values |
Total input power, Nm/s; Output power to load, Nm/s; Torque at axis of rotating machine,Nm; Speed, rpm; (for induction and dc machines an external frequency input via analog input 0 is required); Efficiency: Eta = Output power / Input power; Slip: Slip=(fi - fo)/fi |
Motor version including analog input, RS-232, and software. |
Dynamic
Torque |
Dynamic torque in air gap of rotating machines versus time or speed; moment of inertia of rotor. |
|
|
|
Harmonic Analysis |
Frequency range of fundamental 4Hz–50kHz |
Harmonic 1–63 |
| |
Accuracy: harmonic current and voltage, same as rms current and rms voltage |
Add accuracy percentage figures of values involved in computation. |
| |
Computed values: harmonic power, harmonic phase angle (power factor); harmonic impedance. |
| |
|
Frequency |
2Hz-100kHz; A; V, or external triggered: ±0.1% |
| |
|
Integrator |
Energy, Accuracy: Wh, VAh; Basic accuracy of integrated quantity. |
| |
|
|
Data Logging |
Output values, speed and duration is programmable; maximum speed: 10 values from a 3-phase system in 20ms. |
Range of signal frequency 5Hz to 1kHz |
| |
|
Current harmonics |
Current harmonics in a 3-phase system are determined according to IEC1000-3-2 |
| |
|
|
Display |
Blue liquid crystal graphic display with FL backlight |
64x120mm;128x240 pixels |
| |
|
Power |
AC, 50–60Hz; Fuse; 0.2AF, Power 115/230V; 15VA |
| |
|
|
Dielectric Strength |
Current inputs to case; Voltage inputs to case; Line input to case |
3kV; 2kV; 3kV 50Hz/1 min |
| |
|
|
Dimensions |
H x W x D; weight |
150x235x320mm; 4kg |
| |
|
Options |
RS232 interface |
|
10 High speed analog inputs (1 frequency, 9 dc voltage) |
fx, ±5V |
|
10 Analog outputs |
±5V |
|
Windows operating software 95,98,NT,ME,2000,XP |
Versions
4107A-1/0.3L
|
Economy Single Phase High Speed Power Analyser,
0.3% accuracy, saves 12 instrument settings, no data
logging, no IEC1000-3-2. |
4107A-1/0.3
|
Single Phase High Speed Power Analyser, 0.3%
accuracy, saves 12 instrument settings, includes
data logging, no IEC1000-3-2. |
4107A-1/0.1
|
Single Phase High Speed Power Analyser, 0.1%
accuracy, saves 12 instrument settings, includes
data logging and IEC1000-3-2. |
4107A-1/0.05
|
Single Phase High Speed Power Analyser, 0.05%
accuracy, saves 12 instrument settings, includes data
logging and IEC1000-3-2. |
4107A-3/0.3L
|
Economy Three Phase High Speed Power Analyser, 0.3%
accuracy, saves 12 instrument settings, no line-to-line
measurement, no data logging, no IEC1000-3-2. |
4107A-3/0.3
|
Three Phase High Speed Power Analyser, 0.3% accuracy,
saves 12 instrument settings, includes line-to-line
measurement and data logging, no IEC1000-3-2. |
4107A-3/0.1
|
Three Phase High Speed Power Analyser, 0.1% accuracy,
saves 12 instrument settings, includes line-to-line
measurement, data logging, and IEC1000-3-2. |
4107A-3/0.05
|
Three Phase High Speed Power Analyser, 0.05% accuracy,
saves 12 instrument settings, includes line-to-line
measurement, data logging, and IEC1000-3-2. |
4107A-3/0.05M
|
Three Phase High Speed Power Analyser for dynamic
motor testing torque transducer required), 0.05%
accuracy, saves 12 instrument settings, includes line-to-line
measurement, dynamic torque easurement, EC1000-3-2,
RS-232 interface, frequency/analog in-out, data logging
and operating software for motor testing. |
4107A-3/0.05T
|
Three Phase High Speed Power Analyser for transformer
testing according to IEC60076-1, 0.05% accuracy, saves
12 instrument settings, includes line-to-line measurement,
data logging, IEC1000-3-2, RS-232 interface, and
operating software. |
Accessories
ACS1
|
Current clamp with connector to 4107A clamp input; 0-200A
/ 0-1000A, DC-1kHz, 2% |
ACS2
|
Current clamp with connector to 4107A clamp input; 0-
200A, DC-20kHz, 1% |
ACS3
|
Soft carrying case for 4107A |
ACS4
|
Set of test leads, max. 32A, 1.5m (2 red; 2 black) |
ACS5
|
Clamp input connector |
ACS6
|
Service Manual 4107A |
ACS7
|
Rack Mounting Kit |
ACS8
|
Calibration Certificate traceable to national standards |
ACS9
|
USB - RS232 Adapter cable, USB 1.1 compatible, Windows
98/2000/ME/XP, > 1Mbps data transfer rate |
Options
01 |
High Speed RS232 Interface, external synchronization input, Windows Operating Software (95,98,NT,2000,ME,XP) without data logging capabilities, without IEC1000-3-2 |
02 |
High Speed RS232 Interface, external synchronization input, trigger input, Windows Operating Software (95,98,NT,2000,ME,XP) including software for high speed data logging and IEC1000-3-2 testing |
03 |
One frequency input with selectable frequency range, nine analog inputs (±5V / ±10V), ten analog outputs(±5V) |
04 |
0-100A Three Phase Current Sensor Module including supply |
05 |
0-300A, 0-3000A flexible current clamps with connector to clamp input of 4107A (1 per phase). Basic accuracy: 1% 50/60 Hz |
For more information about this product contact Tinsley
|