Submarine Cable Test Equipment
Long Haul Submarine Cable Test Set Model 5902
The Tinsley 5902 Long Haul Submarine Cable Test Set brings the latest technology to the tried and tested DC methods of cable fault location. The more common test procedures which are associated with the location of types of cable fault such as "open circuits" and "shunt faults" are pre-programmed into the instrument. This allows the procedure to be carried out automatically therefore eliminating operator errors and reducing the uncertainty of the prediction of fault position. The instrument may be set for a wide range of voltage and current limits making it suitable for use with most submarine communication cable systems.
Safety being an important feature, the instrument gives a continuous indication of the state of charge of the cable under test and will automatically disallow current, voltage or polarity changes to be made until any voltage on the cable has fallen to a level which is safe for both the cable and the instrument. A safety interlock operates to remove high voltage from the output should a cable patch lead be removed whilst a test is in operation.
The setting up of the instrument is menu driven with prompts being displayed on an eight line LCD display. This display is also used to indicate at which stage a test procedure has reached during its implementation. The RS232 interface is designed for full duplex communication. All functions may be controlled via a computer and obtained data may be stored for future analysis. This interface may also be used to enable two 5902's to communicate with each other when carrying out double ended tests such as "no loss of current". After fault detection the electroding generator function may be used to assist the cable repair vessel in locating the cable on the sea bed prior to retrieval and repair.
For more information about this product contact Tinsley
Specifications
See the table below for a run-down of this product's specifications.
Ohmeter - Conductor Resistance Measurement |
Resistance Range |
Display Resolution |
Accuracy (line Voltage 1V to 1000V) |
0W to 100.00W |
0.01Ω |
±0.2Ω |
100.1W to 1000.1W |
0.1Ω |
±0.2W up to 200Ω
±0.1% above 200Ω |
1000W to 10000W |
1Ω |
±0.1% |
10KW to 100KW |
10Ω |
±0.1% at 10KΩ
reducing to ±0.5% at 100KΩ |
| |
|
|
Current Control |
|
Polarity |
Selectable positive "+" or negative "-" |
Level |
May be set from 0.5 to 200mA with resolution 0.1mA |
Compliance |
Selectable at 50V, 100V, 250V, 500V or 1000V |
| |
|
|
Voltage Control mode |
Level may be set 0.5V to 1000V with resolution of 0.1 V |
Drive selectable 20mA or 200mA |
| |
|
|
Capacitance Meter (CAP or IC)
Direct reading capacitance measurements between 0.05µF and 2000µF. Incorporating automatic compensation for leakage and series resistance evenly distributed along cable length.
Range |
Resolution |
Accuracy (using standard caps) |
Measurement Cycle |
0.05 to 2µF |
0.001µF |
±0.005µF |
2 secs @ 1µF |
2 to 20µF |
0.001µF |
±0.2% |
2 secs @ 10µF |
20 to 200µF |
0.01µF |
±0.2% |
20 secs @ 100µF |
200 to 2000µF |
0.1µF |
±0.2% |
200 secs @ 1000µF |
| |
|
|
|
MegOhmmeter - insulation resistance measurement
Selection of voltages between 50V and 1000V. Analogue meter display 10 5 to 10 11 Ohm in 3 ranges. With digital indication on the main display.
Voltage settings |
+50V, 100V, 250V, 500V, or 1000V |
Polarity |
selectable positive "+" or negative "-" |
| |
|
Range |
Applicable Voltage |
Accuracy |
105 Ω to 109 Ω |
50V 100V |
±1dB (105Ω to Ω108Ω ) using Standard Resistors |
106 to 1010 Ω |
250V |
±1dB (106Ω to 109Ω ) using Standard Resistors |
107 to 1011 Ω |
500V 1000V |
±1dB (107Ω to 1010Ω ) using Standard Resistors |
| |
|
Charge Current |
Current limit selectable to 20mA or 200mA nominal |
Electroding Generator (GEN) |
A sine wave generator with selectable current levels and voltage limits |
| |
Frequency |
Selectable either 10Hz, 16.7Hz, 20Hz, 25Hz or 33.3Hz.
Accuracy 0.03Hz |
Level |
Selectable amplitude 100mA or 200mA peak to peak. Accuracy 5% |
Polarity |
Selectable positive "+" or negative "-" |
Voltage limit |
Selectable 50V, 100V, 250V, 500V |
For more information about this product contact Tinsley
Optional Calibration Standards
The Tinsley Model 5906A and 5906B Calibration Standards enable the 5902 test set to be calibrated aboard ship by the operator.
Note: Because of the technical nature of Submarine Cable Testing Equipment and the use and support requirements across international boundaries, the equipment can only be purchased direct from the manufacturer: - H. Tinsley & Co. in the UK and not through international agents.
|