Tinsley Precision Instruments
Tinsley Precision Instruments

page location: home > products > submarine cable test equipment > model 5910

Submarine Cable Test Equipment

Portable Short-Haul Submarine Cable Test Set Model 5910

Portable Short-Haul Submarine Cable Test Set Model 5910The Tinsley 5910 is a portable Short Haul Submarine Cable Test Set that brings the latest technology to the tried and tested DC methods of cable fault location.

Common test procedures which are associated with the location of cable fault such as "open circuits" and "shunt faults" are pre-programmed into the instrument. This allows the procedure to be carried out automatically therefore eliminating operator errors and reducing the uncertainty of fault position prediction.

The instrument may be set for a range of voltages and currents making it suitable for use with most un-repeatered submarine communication cable systems.

The RS232 interface is designed for full duplex communication with the instrument. All functions may be controlled via a computer and obtained data may be stored for future analysis. This interface may also be used to enable two 5910's to communicate with each other via a computer when carrying out double ended tests such as "no loss of current".

A basic electroding generator function is included which can assist the cable repair vessel in locating the cable on the sea bed prior to retrieval and repair.

For more information about this product contact Tinsley

A rack mount version the Tinsley Model 5910R is also available

Specifications

See the table below for a run-down of this product's specifications.

 

Ohmmeter - Conductor resistance measurement
Resistance Range
Resolution
Accuracy (within compliance of 1V to 140V)
0.2Ω to 100.00Ω
0.01Ω
±0.2 Ω
100.00Ω to 1000.00Ω
0.1Ω
±0.2W up to 200Ω
±0.1% above 200Ω
1kΩ to 10kΩ
±0.1% at 1kΩ
reducing to
±0.2% at 10kΩ
10kΩ to 100kΩ
10 Ω
±0.2% at 10kΩ
reducing to
±2% at 100kΩ

 

Current Control

     

Range 

Resolution 

Accuracy

0.5 to 10.0mA
0.1mA
±2µA
10.1mA to 100mA
0.1mA
±20µA
   
Polarity 

Positive "+" or negative "-" selectable by thumbwheel switch

   

MegOhmmeter - Insulation resistance measurement

Voltage settings +50V, 100V, 250V, 500V, or 1000V
Polarity selectable positive "+" or negative "-"

Range 
Applicable Voltage
Accuracy
105Ω to 109Ω
50V, 100V
±1dB (105 to 108 Ω ) using Standard Resistors
106Ω to 1010 Ω
250V 
±1dB (106 to 109 Ω ) using Standard Resistors
107Ω to 1011Ω
500V, 1000V
±1dB (107 to 1010 Ω ) using Standard Resistors
     

Capacitance 

Direct reading capacitance measurements between 0.05µF and 2000µF. 

Range 
Resolution 
Accuracy (using standard caps)
Measurement Cycle
0.05 to 2µF
0.001µF 
±0.005µF
2 secs @ 1µF
2 to 20µF 
0.001µF
±0.2% 
2 secs @ 10µF
20 to 200µF
0.01µF
±0.2%
20 secs @ 100µF
200 to 2000µF
0.1µF
±0.2%
200 secs @ 1000µF


Electroding Generator (GEN) 

Output polarity either positive to LINE or negative to LINE

Control 
Constant current - compliance 0.1 to 50V
Frequency 
25Hz or 16.7Hz
Output 
50mA + 50mA sin wt
(i.e. minimum 0mA, maximum 100mA, synthesised, sinusoidal current
   

For more information about this product contact Tinsley

Note: Because of the technical nature of Submarine Cable Testing Equipment and the use and support requirements across international boundaries, the equipment can only be purchased direct from the manufacturer: - H. Tinsley & Co. in the UK and not through international agents.

 

Hartest - Height of Precision